%0 Conference Paper %F Oral %T Fault Tolerant Control of Six-Phase Induction Generator for Wind Turbines %+ Laboratoire des technologies innovantes - UR UPJV 3899 (LTI) %+ LAboratoire PLasma et Conversion d'Energie (LAPLACE) %A Pantea, Alin %A Yazidi, Amine %A Betin, Franck %A Carrière, Sébastien %A Sivert, Arnaud %A Capolino, Gerard-Andre %Z IEEE International Electric Machines and Drives Conference (IEMDC), Miami, FL, MAY 20-24, 2017 %< avec comité de lecture %B 2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC) %C Miami, United States %8 2017-05-20 %D 2017 %Z Engineering Sciences [physics]Conference papers %X In this paper, simulation and experimental results of a fault tolerant of a squirrel cage six-phase induction generator (SC6PIG) are presented. The proposed generator, suitable for grid connected multiphase wind energy generating system, is composed of a 24kW SC6PIG prototype connected to a full scale back-to-back converter structure. The aim of this paper is to validate experimentally the model of the whole fault tolerant control system based on the Field Oriented Control (FOC) scheme. Simulation and experimental responses are compared for the same generation profiles. %G English %L hal-03629902 %U https://u-picardie.hal.science/hal-03629902 %~ UNIV-TLSE3 %~ CNRS %~ UNIV-PICARDIE %~ LAPLACE %~ U-PICARDIE %~ LTI %~ TOULOUSE-INP %~ UNIV-UT3 %~ UT3-INP %~ UT3-TOULOUSEINP