Doppler Echocardiographic Indices Are Specific But Not Sensitive to Predict Pulmonary Artery Occlusion Pressure in Critically Ill Patients Under Mechanical Ventilation
Résumé
OBJECTIVES: The objective of this study was to prospectively evaluate the ability of transthoracic echocardiography to assess pulmonary artery occlusion pressure in mechanically ventilated critically ill patients. DESIGN: In a prospective observational study. SETTING: Amiens University Hospital Medical ICU. PATIENTS: Fifty-three mechanically ventilated patients in sinus rhythm admitted to our ICU. INTERVENTION: Transthoracic echocardiography was performed simultaneously to pulmonary artery catheter. MEASUREMENTS AND MAIN RESULTS: Transmitral early velocity wave recorded using pulsed wave Doppler (E), late transmitral velocity wave recorded using pulsed wave Doppler (A), and deceleration time of E wave were recorded using pulsed Doppler as well as early mitral annulus velocity wave recorded using tissue Doppler imaging (E `). Pulmonary artery occlusion pressure was measured simultaneously using pulmonary artery catheter. There was a significant correlation between pulmonary artery occlusion pressure and lateral ratio between E wave and E ` (E/E ` ratio) (r = 0.35; p < 0.01), ratio between E wave and A wave (E/A ratio) (r = 0.41; p < 0.002), and deceleration time of E wave (r = -0.34; p < 0.02). E/E ` greater than 15 was predictive of pulmonary artery occlusion pressure greater than or equal to 18 mm Hg with a sensitivity of 25% and a specificity of 95%, whereas E/E ` less than 7 was predictive of pulmonary artery occlusion pressure less than 18 mm Hg with a sensitivity of 32% and a specificity of 81%. E/A greater than 1.8 yielded a sensitivity of 44% and a specificity of 95% to predict pulmonary artery occlusion pressure greater than or equal to 18 mm Hg, whereas E/A less than 0.7 was predictive of pulmonary artery occlusion pressure less than 18 mm Hg with a sensitivity of 19% and a specificity of 94%. A similar predictive capacity was observed when the analysis was confined to patients with EF less than 50%. A large proportion of E/E ` measurements 32 (60%) were situated between the two cut-off values obtained by the receiver operating characteristic curves: E/E ` greater than 15 and E/E ` less than 7. CONCLUSIONS: In mechanically ventilated critically ill patients, Doppler transthoracic echocardiography indices are highly specific but not sensitive to estimate pulmonary artery occlusion pressure.